hp3585b频谱分析仪/ 以上图片为现货实物拍摄图/ 欢迎有意者来电垂询/ 销售/ 64021565/ . hp3585b 频谱仪扫频仪 (带跟踪源) 体积重量: 23x43x64 cm , 40kg
频率范围 20hz至40mhz 分辨力 0.1hz 跟踪源 [ tracking generator ] rbwZui低可达 3hz 测量范围 -137dbm 至 +30dbm 幅度精度 ±0.4db 动态范围 80db 同时具备三种输入阻抗 50ω, 75ω, 1 mω 1001x1024 数字存储显示 面板设置和光标直读 输入衰减器自动换档 [ autoranging input attenuator ] gpib编程接口,此接口也可直接打印 [ gpib with direct-plot capability ] 尤其适合滤波器测试, 谐振点测试 hp3585b 详细指标--pdf文档 hp3585b spectrum analyzer gpib software frequency measurement range 20 hz to 40.1 mhz displayed frequency span range: 0 hz to 40.1 mhz variable with 0.1 hz resolution or 10 hz to 40 mhz in 1, 2, 5 accuracy: -0% + 0.2% of frequency span setting displayed center, start/stop, and manual frequency range: 0 hz to 40.1 mhz with 0.1 hz resolution accuracy: 1 x 10-7/ month of frequency marker readout accuracy ± 0.2% of frequency span ± resolution bandwidth counter accuracy ± 0.3% hz ± 1 x 10-7/month of counted frequency for a signal 20 db greater than other signals and noise in the resolution for bandwidth setting resolution bandwidths range 3 db bandwidths of 3 hz to 30 khz in a 1, 3, 10 sequence accuracy ± 20% at the 3 db points selectivity 60 db/3 db <11.1 amplitude measurement range 1 m ωinput: -31 nvrms to +7.08 vrms 50/75 ωinput: -137 dbm to +30 dbm all receiver inputs can be overdriven by up to 12.3 db above the range setting, with some degradation in distortion performance. displayed range scale: 10 division crt vertical axis with reference level at the top graticule line calibration: 10, 5, 2 and 1 db/division from the reference level input range -25 dbm to +30 dbm in 5 db steps reference level range (relative to input range) -100 db to +10 db marker amplitude accuracy midscreen at the reference level use reference level accuracy from +30 dbm to -115 dbm, add amplitude linearity below -115 dbm. anywhere on screen add reference level accuracy, amplitude linearity and frequency response dynamic range spurious responses (image, out of band, and harmonic distortion) 50/75 ω input: <-80 db referred to a single signal equal to or less than input range 1 m ω input: <-80 db except second harmonic distortion <-70 db intermodulation distortion 50/75 ω input: <-80 db referred to the larger of two signals each 6 db below range except 2nd order im from 10 mhz to 40 mhz <-70 db 1 m ω input: <-70 db residual responses (no signal at input) <-120 dbm using -25 dbm range residual phase noise (typical at 40 mhz, -10 dbm input) 5 khz offset: -112 dbc/hz 100 khz offset: -120 dbc/hz sweep modes continuous, single or manual trigger free run, line, or external time 0.2 s full sweep to 200 s/hz of frequency span (swept time excluding auto calibration cycles) input signal inputs 50/75 ω: 26 db return loss, bnc connector 1 m ω: ± 3% shunted by <30 pf, bcn connector maximum input level 50/75 ω: 13 v peak ac plus dc relay protected against overloads to 42 v peak 1 m ω input: 42 v peak ac plus dc (derate by factor of two for each octave above 5 mhz) external trigger input negative going ttl level or contact closure required to initiate sweep external reference input 10 mhz (or subharmonic to 1 mhz), 0 dbm minimum level output tracking generator level 0 dbm to -11 dbm with a single turn knob frequency accuracy ± 1 hz relative to analyzer tuning frequency response ± 0.7 db impedance 50 ω; > 14 db return loss probe power +15 vdc, -12.6 vdc; 150 ma max. if 350 khz, -11 dbv to -15 dbv at the reference level video 10 v at the reference level frequency reference 10.000 mhz ± 1 x 10 -7/month, +10 dbm into 50 ω hp-ib interface functions sh1, an1, t6, l4, sr1, rl1, tp0, dc1, dt1, c0
|